- Robust, compact, and light
- Fast sensor response
- Multiple sensor range options with high accuracy
- Replaceable battery with two-year runtime
| Display: | Segment LCD |
| Keypad: | Two buttons |
| Case Materials: | Polycarbonate with a protective rubber over-mold |
| Alarms: | Visual (two red LEDs); Audible (95db); Vibration, TWA, STEL |
| Dimensions: | 82 x 60 x 27 mm ( 3.23″ x 2.36″ x 1.07″ ) |
| Weight: | 85g (3oz) |
| Ingress Protection: | IP 66/68 |
| Temperature Range: | -40 °C to 50 °C (-40 °F to 122 °F) |
| Humidity Range: | 5% to 95% Non-condensing |
| Sensors: | CO, H2S – Electrochemical sensor technology |
| Sensor Measuring Ranges: | Gas Type Range Resolution T90 CO 0-1000 ppm 1 ppm ≤10s CO 0-2000 ppm 1 ppm ≤10s H2S 0-100 ppm 0.1 ppm ≤10s H2S 0-200 ppm 0.1 ppm ≤10s H2S 0-500 ppm 0.1 ppm ≤10s |
| Battery: | 3.6 V Primary Lithium-thionyl chloride (Li-SOCl2), 1.5AH, 2/3AA , replaceable |
| Run Time: | Up to two years of runtime, depending on operating conditions, the amount of time the unit is in alarm, and the use of the unit’s confidence indicator. |
| Certifications: | International: IECEX: Ex ia IIC T4 Ga; Ex ia I Ma North America: UL: Class I, Division 1, Groups A, B, C, D T4 Class I, Zone 0, AEx ia IIC T4 Ga CSA: Ex ia IIC T4 Class I, Division 1, Groups A, B, C, D T4 Europe: ATEX: Ex ia IIC T4 Ga; Ex ia I Ma CE: Directive 2014/30/EU, EN50270 Directive 2011/65/EU and 2015/863/EU China: China Ex: Ex ia IIC T4 Ga China MA: Ex ia I Ma China CPA |