Skip to main content
x

Tiger XT Select Portable Benzene Gas Detector

Rapidly detects Benzene & Total Aromatic Compounds (TACs) providing the most accurate reliable data available!
Utilising the high output ION Science 10.0 eV lamp, the Tiger XT Select (XTS) portable benzene gas detector is capable of detecting Total Aromatic Compounds (TACs) including Benzene, Toluene and Acetone. The instrument is supplied with a pack of benzene pre-filter tubes to detect benzene  selectively. The tube can be easily attached to ensure rapid detection and selective measurement of benzene. Throughout the measurement process, Tiger XT Select benzene gas detector continuously displays real time data. Tiger XT Select can also provide 15 minute short term exposure limits (STELs) and 8 hour time weighted averages (TWAs) for Total Aromatic Compounds (TACs).

Manufacturer: Ion Science

Tiger XT Select Portable Benzene Gas Detector

Overviews

The Tiger XT Select handheld benzene gas detector can be used in standard operational mode without the use of a benzene pre-filter tube to deliver active indications of volatile organic compounds (VOCs).

Features

Improved Robust Design
The instrument’s rugged body can withstand harsh environments
Long Rechargeable Battery Life
When fully charged, the lithium-ion battery can last up the 24 hours
IP65 Ingress Protection
Protection against a range of conditions and weather temperatures 
Fast Response Time & Clear Down
<2 second response time, one of the fastest and most accurate on the market
Instantaneous Alarms
Bright visible alarms: RED & AMBER with loud sounder (95 dBA at 300 mm (12”))
Humidity Resistant and Anti-Contamination Design
Patented Fence Electrode Technology ensures optimal performance and extends run time

Video

Specification

Minimum sensitivity (PPM model): • Standard running mode: 0.1 ppm
• TAC mode: 0.01 ppm
• Tube mode 0.01 ppm (res. 0.001 ppm)
Minimum sensitivity (PPB model): • Standard running mode: 0.001 ppm
• TAC mode: 0.001 ppm
• Tube mode: 0.01 ppm (res. 0.001 ppm
Maximum Reading: • Standard mode up to 20,000 ppm or 20,000 mg/m3*
• Tube mode 200 ppm or 639 mg/m3 benzene
Response Time: 130 seconds at 20oC (variable), Progressive indication of benzene breakthrough is displayed in real time
Accuracy: ± 10% display reading ± one digit Benzene (tube mode)
Battery Life: • Li-ion: life up to 24 hours, charge time 8 hours
• Alkaline: 3 x AA, typically  8.5 hours life
Lamps: 10.0 eV Krypton PID lamp
Data Logging: 120,000 data log points including date and time stamp
Communication: Direct USB 1.1
Calibration:  2 and 3 point calibration (via calibration kit accessory)
Alarm: • Flashing LEDs Amber (low alarm) Red (high alarm)
• Sounder 95 dBA at 300 mm (12”)
• Vibration on alarm
• Pre-programmed TWA and STEL*
Flow Rate:  ≥ 220 ml/min (with blocked flow alarm)
Temperature: • Operating: -20 to 60 oC, -4 to 140 oF
• Humidity: 0-99% RH (non condensing)
Protection: • Designed to IP65
• EMC tested to EN61326-1:2013 & EN50270:2015 & CFR 47:2008 Class A
Weight & Dimensions: 370mm (H) x 91 mm (W) x 60 mm (D), 870g
Intrinsically Safe Approvals: • II 1G Ex ia IIC T4 Ga
• Tamb = - 15 oC ≤Ta ≤+45 oC (with lithium ion battery pack)
• Tamb = - 15 oC ≤Ta ≤+40 oC (with alkaline battery pack)
• ITS-I22ATEX35111X
• IECEx ITS 22.0025X 
• ITS22UKEX0635X
• 3193491 conforms to UL Std. 913, 61010-1 
• Certified to CAN/CSA std. C22.2 No. 61010-1
• Class 1 Division 1. Approval for Groups A, B, C & D, T4

 

Q&A

Yes, for your Tiger XT, Tiger XT Select, Tiger XTL and the Cub and Cub TAC.

The instrument firmware can be upgraded via the PC software. Please refer to the instrument user manual for further details.

ION Science recommends that factory service and calibration is carried out every 12 months.
Please email: info@panindochina.com.vn for further information.
In between factory service and calibration, users should implement a regular maintenance regime.

Filter replacement should be carried out as part of regular instrument maintenance, or immediately if signs of contamination appear. Frequency of replacement is typically after 100 hours, however this may differ depending on application and environmental conditions.

For more information, please contact info@panindochina.com.vn

A gas search tool is available on the ION Science website.
If your chemical cannot be found when searched, please contact info@panindochina.com.vn and advise the chemical name, formula and (‘CAS No.’) to ensure no ambiguity in our recommendation.