The Tiger XTL is a ground breaking low cost entry level VOC detector with all the essential functions you need to detect VOCs. The instrument has the lowest running costs on the market with inexpensive disposable parts, lamps and filters. This variant of the hugely popular Tiger XT VOC detector is low on cost but high on performance. Its revolutionary, patented PID sensor technology with resistance and anti-contamination design provides market leading accuracy and run time. Combined with 24 hour battery life, these features maximise field time by minimising erroneous readings in high humidity and drift in hard environments.

Manufacturer: Ion Science

Tiger XTL Portable VOC Gas Detector

Overviews

The Tiger XTL portable VOC gas detector is ETL (Electrical Testing Laboratories), KGS (Korean Gas Safety), IECEx (International Electrotechnical Commission System for Certification to Standards Relating to Equipment for Use in Explosive Atmospheres) certified. It is also ATEX approved meaning the instrument is intrinsically-safe.

Features

Improved Robust Design
The instruments rugged body can withstand harsh environments
Long Rechargeable Battery Life
When fully charged, the lithium-ion battery can last up the 24 hours
IP65 Ingress Protection
Protection against a range of conditions and weather temperatures 
Fast Reponse Time & Clear Down
<2 second response time, one of the fastest and most accurate on the market
Instantaneous Alarms
Bright visible alarms: RED & AMBER with loud sounder (95 dBA at 300 mm (12”))
Humidity Resistant and Anti-Contamination Design
Patented Fence Electrode Technology ensures optimal performance and extends run time

Video

Specification

Minimum Resolution: 0.1 ppm
Maximum Reading:  5,000 ppm
Response Time: T90 < 2 seconds
Accuracy:  ± 5% display reading ± one digit
Linearity: 5% display reading ± one digit
Battery Life:  Li-ion: life up to 24 hours continual use
Lamps: 10.6 eV Krypton PID lamp (standard)
Data Logging: Push-to-log, 128 zones, 80,000 data points
Calibration:  • Standard calibration 100 ppm isobutylene
• Custom calibration capability
Alarm:  • Flashing LED and 95 dBA at 300mm (12”) audible sounder
• Selectable vibrating alarm
Flow rate:  ≥ 220 ml/min (with blocked flow alarm)
Temperature: • Operating: -20 to 60 0C, -4 to 140 0F 
• Humidity: 0-99% RH (non condensing)
Protection • Designed to IP65
• EMC tested to EN61326-1:2013 & EN50270:2015 & CFR 47:2008 Class A
Weight & Dimensions: • 370 mm (H) x 91 mm (W) x 60 mm (D) 
• 870g
Intrinsically Safe Approvals • II 1G Ex ia IIC T4 Ga
• Tamb = - 15 0C ≤Ta ≤+45 0C (with lithium ion battery pack)
• Tamb = - 15 0C ≤Ta ≤+40 0C (with alkaline battery pack)
• ITS-I22ATEX35111X
• IECEx ITS 22.0025X 
• ITS22UKEX0635X
• 3193491 conforms to UL Std. 913, 61010-1 
• Certified to CAN/CSA Std. C22.2 No. 61010-1

Q&A

Yes, for your Tiger XT, Tiger XT Select, Tiger XTL and the Cub and Cub TAC.

The instrument firmware can be upgraded via the PC software. Please refer to the instrument user manual for further details.

ION Science recommends that factory service and calibration is carried out every 12 months.
Please email: info@panindochina.com.vn for further information.
In between factory service and calibration, users should implement a regular maintenance regime.

Filter replacement should be carried out as part of regular instrument maintenance, or immediately if signs of contamination appear. Frequency of replacement is typically after 100 hours, however this may differ depending on application and environmental conditions.

For more information, please contact info@panindochina.com.vn

A gas search tool is available on the ION Science website.
If your chemical cannot be found when searched, please contact info@panindochina.com.vn and advise the chemical name, formula and (‘CAS No.’) to ensure no ambiguity in our recommendation.