Tango® TX1 Single-Gas Detector
Tango® TX1 Single-Gas Detector
Eliminate distractions with a lightweight and wearable personal monitor that offers maintenance-free gas detection. A two-year runtime and patented DualSense® Technology increase worker safety, regardless of bump test frequency, while reducing overall costs.
Manufacturer: Industrial Scientific
Features
- DualSense Technology to reduce the risk of sensor failure
- Easy-to-read display
- Replaceable batteries that eliminate the need for daily charging.
Specification
Display: | Segment liquid crystal display (LCD) |
Keypad: | Two buttons |
Case Materials: | Case top: Polycarbonate with a protective rubber overmold. Case bottom: Conductive polycarbonate |
Alarms: | Three strobe-emitting visual alarm LEDs (two red; one blue) 100 decibel (dB) audible alarm at a distance of 10 cm (3.94 in); Vibration alarm |
Dimensions: | 99 x 51 x 35 mm (3.9 x 2.0 x 1.4 in) |
Weight: | 126.0 g (4.4 oz) |
Temperature Range: | -40 °C to 50 °C (-40 °F to 122 °F) ** |
Huminity Range: | 15% to 95% Non-condensing (continuous) |
Sensors: | CO, CO/H2, H2S, NO2, SO2 – Electrochemical sensor technology |
Battery: | 3.6 V Primary lithium-thionyl chloride (Li-SOCl2); 1.5AH, 2/3AA; replaceable; non rechargeable; always on; up to 2-year run time depending on operating conditions |
Data Logging: | 3 months at 10-second intervals |
Event Logging: | 60 alarm events |
Certifications: | INGRESS PROTECTION IP66/67 -40 °C to 50 °C (-40 °F to 122 °F) ATEX: Ex ia I Ma; Ex ia IIC T4 Ga; Equipment Group/Category: I M1/II 1G IECEx: Ex ia I Ma; Ex ia IIC T4 Ga UL (C-US): Cl I, Gr A-D, T4; Cl II, Gr E-G; Cl I, Zone 0, AEx ia IIC T4 |
Q&A
The Tango TX1 is Guaranteed for Life™ to ensure customers always have the highest quality monitor.
No. The primary advantage of DualSense™ Technology would be lost if converted to a two-gas monitor. If you are looking for a two-gas monitor
DualSense™ Technology uses two of the same sensors for detection of a single gas. Readings are passed through a proprietary algorithm and a single monitor reading is displayed. This decreases the likelihood of a monitor not being able to detect gas out in the field, making DualSense monitors safer than single-sensor monitors.
Yes. Sensors are changeable, allowing the user to convert the Tango from one gas type to another.
Yes. A worker will still be protected and can continue working in the field if the sensor fails. Because of sensor redundancy, if a sensor were to fail in the field, the monitor will still continue to operate normally. In addition, if a sensor fails a calibration or a zero fault has occurred, Tango will operate the same as any other single-sensor monitor would.
The Tango uses sensor redundancy, reducing the likelihood of the monitor’s inability to detect gas. Below is a chart that shows the monitor failure rate of a single sensor monitor versus a monitor with DualSense Technology when bump tested daily or not bump tested at all. In either case, the Tango elevates the level of safety regardless of the customer’s current bump test policy.
Single-Sensor DualSense Technology
Daily Bump Test Failure is 1 in 1,265 Failure is 1 in 116,257 — 92 Times Safer
No Bump Testing Failure is 1 in 286 Failure is 1 in 21,319 — 74 Times Safer
Wearing the Tango TX1 with DualSense™ Technology makes you one of the safest single-gas monitor users in the world. Using redundant sensors for detection of the same gas eliminates the pain of balancing cost, safety, and bump test frequency. Additionally, with a two-year battery life, the costs of monitor replacement are eliminated and downtime is reduced.