MX6 iBrid® Six-Gas Monitor
MX6 iBrid® Six-Gas Monitor
Take your gas detection capabilities to new heights with the MX6 iBrid®. With the ability to monitor up to six gases at once, twenty-four sensor options, and a robust list of configurable settings, the MX6 iBrid easily adapts to your safety needs.
Manufacturer: Industrial Scientific
Features
- 24 “Plug-and-Play” field-replaceable sensors including PID and Infrared options
- Up to 6 gases monitored simultaneously
- Simple, user-friendly, customizable, menu-driven navigation
- Five-way navigation button
- Durable, concussion-proof overmold
- Optional integral sampling pump with strong 30.5 meter (100 feet) sample draw
- Full-color graphic LCD is highly visible in a variety of lighting conditions
- Powerful, 95 dB audible alarm
Specification
Case Material: | Lexan/ABS/Stainless Steel with protective rubber overmold |
Dimensions: | 135 x 77 x 48 mm (5.3 x 3.05 x 1.9 in) without Pump 193 x 77 x 56 mm (7.6 x 3.1 x 2.2 in) with Pump |
Weight: | 409 g (14.4 oz) typical, without Pump 511 g (18.0 oz) typical, with Pump |
Display/Readout: | Color Graphic Liquid Crystal Display |
Power Source/Run Times: | Rechargeable, Extended-Range Lithium-ion Battery Pack (36 hours) without Pump Rechargeable, Extended-Range Lithium-ion Battery Pack (20 hours) with Pump Replaceable AA Alkaline Battery Pack (10.5 hours) without Pump |
Operating Temperature Range: | -20 ºC to 55 ºC (-4 ºF to 131 ºF) |
Operating Humidity Range: | 15% to 95% non-condensing (continuous) |
Certifications: | INGRESS PROTECTION IP64 ANZEx: Ex ia s Zone 0 I; Ex ia s Zone 0 IIC T4 ATEX: Ex ia IIC T4 Ga; II 1G (or Ex d ia IIC T4 Gb IR sensor); Ex ia I; Equipment Group and Category: I M1/II 1G China CPC: Metrology Approval China Ex: Ex ia d I/IIC T4 CMA: Approval for Mining Products; CH4, O2, CO, CO2 CSA: Cl I, Gr A-D T4; Ex d ia IIC T4 EAC: PBExiadI X; 1ExiadIICT4 X IECEx: Ex ia I (Ex ia d I IR sensor); Ex ia IIC T4 Ga; Ex d ia IIC T4 Gb INMETRO: Ex ia IIC T4 Ga KC: Ex d ia IIC T4 KIMM: Ex d ia IIC T4 MDR: Registration of Plant Design; CH4, O2, CO, H2S, NO2 MSHA: 30 CRF, Part 22, Intrinsically safe for methane/air mixtures PA-DEP: BFE 114-08 Permissible for PA Bituminous Underground Mines UL: Cl I, Div 1, Gr A-D, T4; Cl II, Groups F G; Cl l, Zone LEL 0, AEx ia d IIC T4 (or AEx ia d IIC T4 IR sensor |
Q&A
The MX6 iBrid can detect up to six gases simultaneously using a mix of Industrial Scientific’s best monitoring technologies.
As your work changes, so does the MX6 iBrid. You can eliminate the need for multiple monitors with hundreds of sensor combinations you can easily change in the field. An internal motorized pump enables remote sampling, and an optional convertible kit allows you to detect accurate benzene levels. The MX6 iBrid provides the advanced gas detection you need for sampling and permitting tasks and excels in industries such as oil and gas, petrochemicals, and metal production.
Gases detected: LEL (methane), LEL (pentane), PID, IR, Cl2, ClO2, CO, CO high, CO/H2 low, CO/H2S, H2, H2S, HCL, HCN, NH3, NO, NO2, O2, PH3, PH3 high, SO2.
The MX6 iBrid must be equipped with an SP6 Pump and photoionization detector (PID) to detect benzene gas.
The MX6 utilizes all field replaceable, plug-in sensors. The user can replace any sensor in the field and have the instrument in service after performing a simple field calibration.
Oxygen sensors in the MX6 iBrid will typically last two years. On average, toxic sensors will last 3-4 years and combustible sensors 4-5 years. There is no need to replace these sensors before they indicate a marginal or failed calibration in the MX6.
The catalytic bead combustible gas sensor in the MX6 iBrid requires a minimum of 10% oxygen to provide an accurate reading. In any situation in which the oxygen reading is less than 10%, the combustible gas reading must be considered to be in error. The MX6 can also utilize one of two infrared (IR) sensors to detect combustible gas to 100% LEL or methane to 100% of volume. The infrared sensors do not rely on oxygen and therefore function accurately in an oxygen-deficient atmosphere. It must be noted that the infrared sensors will not respond to hydrogen.
In applications in which hydrogen is present and there is less than 10% oxygen, a 1:1 dilution fitting must be used in the sample line to provide sufficient oxygen to the sensor and get an accurate reading. When using a dilution fitting, the user must always remember that the monitor will display one-half of the actual gas concentration being measured.
As a general rule, the MX6 iBrid with pump is rated to sustain a continuous sample draw for up to 100 feet with 0.125-inch inside diameter sample tubing. However, the pump will provide adequate flow at 0.5 liters per minute up to a vacuum pressure of approximately 30 inches of H2O. The length of the sample tube can exceed 100 feet as long as the vacuum pressure required to draw the sample does not exceed 30 inches of H2O.
The MX6 iBrid is warranted for as long as the monitor is supported by Panindochina Team's